Skip to content Skip to navigation menu
click to open Expanded view
Schneider Electric Schneider Electric (View All Products)

Schneider Electric Vigirex RH10MP, RH21MP, RH99MP, RH197, RHU 50439 Closed Toroid A Type - IA80 - Inner Diameter 80mm - Rated Current 160A

  • Schneider Electric
  • BW#: 00530591
  • Mfr#: 50439
  • UNSPSC#: 39121032
Login or Register to view price
QTY

Features
  • Protection: when detecting significant leakage current in the line it monitors, the relay trips the breaker at the top end of it, through its shunt trip auxiliary
  • Monitoring: signalling leakage current by LED, bargraph or digital display on front, and by an output dry contact. Available in single-line and multi-line variants monitoring up to 12 different distribution lines.
  • Residual current sensitivity ranging from 30 mA to 30 A, fixed or adjustable, for A type relays,
    and 30 mA to 3 A for B type relays
  • Trip time delay ranging from 0 to 4.5 seconds, fixed or adjustable
    o Networks with operating voltage up to 1000 V, and frequency up to 400 Hz
    o lines with current carrying capacity up to 3200 A
    o main switchboards (at the foot of the transformer) in most demanding industrial environments (overvoltage withstand category IV)
  • Type A or type B as per IEC 60 755
  • Compliant with standards:
    o IEC 60 755 and IEC 60947-2 appendix M (certificates by Kema laboratories available)
    o UL 1053 listed, CSA C22.2 N° 144 for North-America
    o EAC for Russia, CCC for China
  • DIN profile, to clip on rail or secure on backplate
  • 72x72mm, for switchboard front plate or door mounting, using clips
    o Closed toroids; for new installations (new switchboards or extensions), with cable capacity up to 630 A for A type relays, 250 A for B type relays
    o Rectangular sensors; for lines with capacity up to 3200 A (busbars, or cables above 630 A)
    o Split toroids; to equip distribution lines already in operation, with cable capacity up to 250 A


  • Applications
  • Electrical networks operating with voltage above 500 V (up to 1000) or frequency higher than 60 Hz (up to 400)
  • Distribution lines with capacity 630 A and above (up to 3200)
  • Upgrade of switchboards already in operation
  • Monitoring and protection at the root of power distribution
  • Three-phase supplied loads including rectifiers : lifts, cranes, HVAC, high-power speed drives, UPS...
  • Single-phase DC boost power supply in some electric vehicle chargers
  • Loads including single-phase speed drives: washing machines, air-conditioning units, heat pumps, food processors)
  • power supply network equipped with harmonic filters


  • Specifications

     • [Ie] rated operational current: 160 A
     • Product or Component type: Earth leakage current sensor
     • Range: Vigirex
     • Device application: Equipment monitoring and control
     • Device short name: IA80
     • Range compatibility: Vigirex RH Plug-in relay
     • Product Certifications : CE
     • Mounting Mode : Fixed (Cables)
     • Fixed (Plain Backplate)
     • Fixed (Profiled Sheet Metal)
     • Fixed (Slotted Backplate)
     • Clip-On (Din Rail)
     • Network Frequency : 45...440 Hz
     • Height : 122 mm
     • Ambient Air Temperature For Operation : -35-70 °C
     • Residual Short-Circuit Withstand Current : 85 Ka / 0.5 S Conforming To IEC 60947-2
     • Standards : IEC 60947-2
     • [Uimp] Rated Impulse Withstand Voltage : 12 Kv
     • Network Type : AC/DC
     • Range Compatibility : Rh10M Residual Current Protection Relay
     • Rh10P Residual Current Protection Relay
     • Rh21M Residual Current Protection Relay
     • Rh21P Residual Current Protection Relay
     • Rh68M Residual Current Protection Relay
     • Rh86M Residual Current Protection Relay
     • Rh86P Residual Current Protection Relay
     • Rh99M Residual Current Protection Relay
     • Rh99P Residual Current Protection Relay
     • Rh197M Residual Current Protection Relay
     • Rh197P Residual Current Protection Relay
     • Rhu Residual Current Protection Relay
     • Rhus Residual Current Protection Relay
     • Rmh Residual Current Protection Relay
     • [Ui] Rated Insulation Voltage : 1000 V
     • Environmental Characteristic : Exposure To Damp Heat Not In Service (25...55 °C, Rh 95 %) : 28 Cycles Conforming To IEC 60068-2-30
     • Salt Mist: Kb/2 Conforming To IEC 60068-2-52
     • Exposure To Damp Heat In Service: Category C2: 48 Hours Conforming To IEC 60068-2-56
     • Connections - Terminals : Screw Connection 0.22-0.22 mm²
     • Net Weight : 0.42 Kg
     • Range : Vigipact
     • Cable Outer Diameter : 40-40 mm: 95-95 mm² (Maximum)
     • Pollution Degree : Level 3 Conforming To IEC 60664-1
     • Ambient Air Temperature For Storage : -55-85 °C
     • Calorific Value : 3.19 Mj
     • Compatibility Code : IA80
     • IP Degree Of Protection : Connectors: IP20
     • IP30
     • Current Transformer Type : A Type Closed Toroid
     • Width : 150 mm
     • Market Segment : Residential
     • Small Commercial
     • Overvoltage Category : Iv
     • Depth : 44 mm
     • [Icw] Rated Short-Time Withstand Current : 100 Ka For 0.5 S
     • Diameter : 80 mm Inner
     • Transformer Ratio : 1/1000

    Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type Earth Leakage Current Sensor
    Alternate Products