Skip to content Skip to navigation menu
click to open Expanded view

Terasaki ZS125GJ4125 T2 ELCB MCCB - 65KA - 30MA - 3A - 4P - 125A - 112 mm x 136 mm x 168 mm

  • TERASAKI
  • BW#: 00354811
  • Mfr#: ZS125GJ4125
  • UNSPSC#: 39121603
Login or Register to view price
QTY

Features
  • Wide range of fault interruption ratings from 25 to 200kA to cater for a wide spectrum of applications

  • MCCB sizes available from 16 to 1600A with various common frames

  • Basic or advanced trip units such AC/DC thermal magnetic, AC electronic, metering and communications types are available


Applications
  • Mining

  • Industrial

  • Commercial


Specifications

  • Service Information: Product is not repairable
  • Product Series: TemBreak 2 ELCB (ZS)
  • Certifications: CE, ASTA
  • Shipping Approvals: Contact NHP
  • Component Type MCCB: MCCB AC
  • Standard Installation Method: Front Connection
  • Trip Unit Protection Type: Adjustable Thermal, Fixed Magnetic
  • Im, Magnetic Trip Current: 1250 A
  • In, Rated Current at 45°C: 125 A @45°C
  • Ics, Rated Service Short-Circuit Breaking Capacity, 440V AC: 25 kA
  • Ics, Rated Service Short-Circuit Breaking Capacity, 525V AC: 22 kA
  • Ics, Rated Service Short-Circuit Breaking Capacity, AC (IEC 60947): 55 % Icu
  • Ics, Rated Service Short-Circuit Breaking Capacity, DC: 100 % Icu
  • Ir, Thermal Trip Current, Max: 125 A
  • Ir, Thermal Trip Current, Min: 80 A
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 220/240V AC: 85 kA @220/240VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 400/415V AC: 65 kA @400/415VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 440V AC: 50 kA @440VAC
  • Icu, Rated Ultimate Short-Circuit Breaking Capacity, 525V AC: 25 kA @525VAC
  • Depth: 68 mm
  • Frame Size: 125 AF size
  • Rated Frequency: 50/60 Hz
  • Height: 155 mm
  • Number of Poles: 4
  • Poles: 4P
  • Electrical Service Life at Un, In: 10000 cycles
  • Mechanical Service Life: 30000 cycles
  • Earth Leakage Trip Time Type: Selectable time
  • Magnetic Trip Type: Fixed type
  • Thermal Trip Type: Adjustable type
  • Uimp, Impulse Withstand Voltage: 8 kV
  • Ui, Rated Insulation Voltage: 525 V (rms)
  • Ue, Rated Operational Voltage, AC, max: 525 V AC
  • Weight: 1.4 kg
  • Width: 120 mm
  • Reverse Connection Of Supply Possible: Yes
  • Earth Leakage Trip Time Setting Range @IΔn: 0, 60, 200, 400, 700 ms or No trip @IΔn
  • IΔn, Earth Leakage Trip Sensitivity Setting Range: 30mA,100mA, 300mA, 500mA, 1A, 3A
  • IΔn, Earth Leakage Trip Sensitivity Type: Selectable sensitivity
  • Minimum sell quantity:

    Order Quantity Multiple:

    Technical Specifications

    Type MCCB AC
    Number of Pole 4P
    Depth 68 mm
    Width 120 mm
    Height 155 mm
    Size 112x136x168mm
    Colour White
    Weight 1.4 kg
    Alternate Products